Tripp Lite - by Eaton PDU 1.4kW Single-Phase Local Metered Automatic Transfer Switch PDU 2 120V 5-15P 15A Inputs 8 5-15R - Unknown

Model: PDUMH15AT
SKU: 11069668
Sold & shipped by

About this product

Tripp Lite's 120V 15A metered PDU system with Automatic Transfer Switching (ATS) is an 8 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned on at 250 milliscond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Supports 1U rackmount installation in a 2 or 4 post rack. Included are 8 NEMA 5-15R outlets, and two 12 ft. 5-15P input power cord. Optional integrated ATS is available for use when two separately derived input power sources are available. The attached power cord serves as the primary AC input cable, while the included detachable power cord serves as the optional-use secondary AC input connection. The PDU system passes the primary input power through to connected equipment whenever line voltage and frequency levels are normal. If the primary input source goes outside of these tolerances or fails altogether, the ATS will automatically switch all PDU output to the secondary line sourced input power (when available) to maintain continuous operation of connected loads without reboots or service interruptions. Once the primary power source is restored, the PDU will automatically switch back to primary sourced input power. The dual input cabling can be configured for UPS maintenance bypass of standard UPS s More from the Manufacturer

Features

  • Tripp Lite by Eaton PDU 1.4kW Single-Phase Local Metered

    Tripp Lite's 120V 15A metered PDU system with Automatic Transfer Switching (ATS) is an 8 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned on at 250 milliscond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Supports 1U rackmount installation in a 2 or 4 post rack. Included are 8 NEMA 5-15R

Specifications

  • Brand
    Tripp Lite
    Model Number
    PDUMH15AT
    Product Name
    Tripp Lite by Eaton PDU 1.4kW Single-Phase Local Metered Automatic Transfer Switch PDU 2 120V 5-15P 15A Inputs 8 5-15R
    Color
    Unknown
    Voltage
    120.0 volts
    Number Of Outlets
    8
Sponsored

Reviews

This product doesn't have any reviews yet.

  • Customer reviews from tripplite.com

    Syndicated rating, 4.5 out of 5 stars with 2 reviews on tripplite.com.

    See all tripplite.com reviews

Compare similar products

Tripp Lite - by Eaton PDU 1.4kW Single-Phase Local Metered Automatic Transfer Switch PDU 2 120V 5-15P 15A Inputs 8 5-15R - Unknown
Tripp Lite - by Eaton PDU 1.4kW Single-Phase Local Metered Automatic Transfer Switch PDU 2 120V 5-15P 15A Inputs 8 5-15R - Unknown
4.5(2)

Tripp Lite's 120V 15A metered PDU system with Automatic Transfer Switching (ATS) is an 8 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned on at 250 milliscond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Supports 1U rackmount installation in a 2 or 4 post rack. Included are 8 NEMA 5-15R outlets, and two 12 ft. 5-15P input power cord. Optional integrated ATS is available for use when two separately derived input power sources are available. The attached power cord serves as the primary AC input cable, while the included detachable power cord serves as the optional-use secondary AC input connection. The PDU system passes the primary input power through to connected equipment whenever line voltage and frequency levels are normal. If the primary input source goes outside of these tolerances or fails altogether, the ATS will automatically switch all PDU output to the secondary line sourced input power (when available) to maintain continuous operation of connected loads without reboots or service interruptions. Once the primary power source is restored, the PDU will automatically switch back to primary sourced input power. The dual input cabling can be configured for UPS maintenance bypass of standard UPS s More from the Manufacturer

Tripp Lite - by Eaton PDU 1.4kW Single-Phase Switched Automatic Transfer Switch PDU 2 120V 5-15P 15A Inputs 8 5-15R - Black

Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Switched PDU features include individually controllable output receptacles. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. More from the Manufacturer

Tripp Lite - by Eaton PDU 3.8kW Single-Phase Local Metered Automatic Transfer Switch PDU Two 200-240V C20 Inlets 8 C13 & 2 - Black
4.0(1)

Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. More from the Manufacturer

Tripp Lite - by Eaton PDU 1.44kW 120V Single-Phase ATS/Local Metered PDU - 8 NEMA 5-15R Outlets Dual 5-15P Inputs 12 ft - Black

Tripp Lite by Eaton PDU 1.44kW 120V Single-Phase ATS/Local Metered PDU - 8 NEMA 5-15R Outlets Dual 5-15P Inputs 12 ft. Cords 1U TAA - Metered Auto Transfer Switch - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1U - Horizontal - Rack-mountable, Wall-mountable - TAA Compliant

Specs

Be the first to ask a question.

We’ll try to get your question answered within 24 hours by a Best Buy customer or brand representative.

No content