Tripp Lite - by Eaton PDU 5.5kW Single-Phase Monitored PDU LX Interface 208/230V Outlets (36 C13/6 C19) L6-30P 10 ft - Black

Model: PDU1420T
SKU: 12250920

Reviews coming soon

Sold & shipped by

About this product

The PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime. The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access. More from the Manufacturer

Features

  • Tripp Lite by Eaton PDU 5.5kW Single-Phase Monitored PDU LX

    The PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime. The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot

  • Extensive outlet options

    Includes 42 outlets (36 C13 and 6 C19) with plug-lock sleeves to secure connections

  • Advanced remote management

    Pre-installed WEBCARDLX with PADM20 firmware enables full remote monitoring and control

  • Real-time load monitoring

    Digital ammeter shows current per load bank and total PDU load for accurate power tracking

  • Robust connectivity

    Supports IPv4, IPv6, SNMP, SSH, and more for versatile network communication

Specifications

  • Brand
    Tripp Lite
    Model Number
    PDU1420T
    Product Name
    Tripp Lite by Eaton PDU 5.5kW Single-Phase Monitored PDU LX Interface 208/230V Outlets (36 C13/6 C19) L6-30P 10 ft.
    Color
    Black
    Amperage
    24 amperes
    Voltage
    230.0 volts
Sponsored

Reviews

This product doesn't have any reviews yet.

Compare similar products

Tripp Lite - by Eaton PDU 5.5kW Single-Phase Monitored PDU LX Interface 208/230V Outlets (36 C13/6 C19) L6-30P 10 ft - Black
Tripp Lite - by Eaton PDU 5.5kW Single-Phase Monitored PDU LX Interface 208/230V Outlets (36 C13/6 C19) L6-30P 10 ft - Black

The PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime. The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access. More from the Manufacturer

Tripp Lite - by Eaton PDU 5.5kW Single-Phase Switched PDU - LX Interface 208/230V Outlets (20 C13 & 4 C19) L6-30P 0U TAA - Black

The PDUMV30HVNETLX 5/5.8kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19). LEDs indicate each outlet's on/off power status. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A digital ammeter allows you to monitor each bank's load in real time to ensure it remains well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access. More from the Manufacturer

APC - NetShelter Metered Rack PDU, 0U, 5.0kW, 200V and 208V, 30A, 36 C13 and 6 C19 outlets - Metered - NEMA L6-30P - 200 - Black
5.0(3)

The APC Metered Rack PDU distributes reliable power within a rack through a single input and multiple output receptacles The AP8841 offers real-time remote monitoring of connected loads and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment The PDU can operate in a maximum ambient air temperature of up to 60°C (140°F) at full load The Network Management Card provides enhanced cybersecurity with secured interfaces and modified password policy The rack PDU integrates with EcoStruxure IT through a Network Management Card and can be accessed and configured via Web, SNMP, and Command Line Interface. User-interactive LCD interface details current, real power, voltage, and energy measurements for local user access. Embedded log memory with historical reporting enables users to meter power usage, optimize energy usage, and plan for capacity The PDU's locking IEC outlets, when used with locking power cords reduce the probability of accidentally disconnecting cords and dropping loads The rack PDU supports daisy-chaining of up to 4 PDUs on a single IP address An environmental monitoring port is available for external temperature/humidity monitoring (sensor sold separately, model AP9335T or AP9335TH) The rack PDU comes with a standard two-year warranty Enables a quick recovery from overload events and breakers are ultra low profile. Packaging Includes PDU, Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable More from the Manufacturer

Tripp Lite - by Eaton PDU 5.5kW Single-Phase Switched PDU Outlet Monitoring 208/230V Outlets (20 C13 & 4 C19) 0U LX - Unknown

The PDUMVR30HVNETLX 5/5.8kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19). LEDs indicate each outlet's on/off power status, and you can monitor each outlet's power consumption remotely or via digital display. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform interface enables full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A digital LED meter allows you to monitor each bank's load in real time to ensure the PDUMVR30HVNETLX is used at maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the includedPDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access. More from the Manufacturer

Specs

Be the first to ask a question.

We’ll try to get your question answered within 24 hours by a Best Buy customer or brand representative.

No content
Sponsored