Tripp Lite - series P036-E06 Standard Power Cord - For Blade Server, Network Switch, Server, Router, Network Device, UPS - Black
Reviews coming soon
About this product
Tripp Lite series P036-E06 Standard Power Cord - For Blade Server, Network Switch, Server, Router, Network Device, UPS, PDU, Computer, Monitor, HDTV, Printer, ... - 12 Gauge - 250 V AC / 20 A - Black - 6 ft Cord Length - IEC 60320 C20 / IEC 60320 C19 - North America - Heavy Duty, P-Lock
Features
C20-to-C19 Power Cable for Network Devices That Require a...
This power extension cord features 12 AWG wire suitable for high power connections, making it a reliable solution for large server applications that require a higher-rated, heavier-gauge cable. The P036-E06 can be used to connect a server, router, network switch or blade server enclosure to a UPS system or PDU. The six-foot (1.8-meter) length helps reduce cable clutter by providing a tailor-made fit between the device and the PDU in a
Forms a Special Locking Connection with a P-Lock Outlet
The P-Lock C20 connector forms a secure connection with a PDU with a P-Lock outlet, including Eaton G4 and newer PDUs with C39 outlets. The P-Lock connection helps reduce costly downtime caused by accidental cable disconnections in a crowded rack or PDU space. The P036-E06 lets you replace a non-locking C19/C20 cable or upgrade an entire PDU application by pairing with an Eaton PDU or other PDU with P-Lock outlets.
Specifications
- Cable Length6.0 feetConnector Type (End 1)IEC/EN 60320 (IEC 320)Connector Type (End 2)IEC/EN 60320 (IEC 320)
Reviews
This product doesn't have any reviews yet.
Compare similar products

Tripp Lite series P036-E06 Standard Power Cord - For Blade Server, Network Switch, Server, Router, Network Device, UPS, PDU, Computer, Monitor, HDTV, Printer, ... - 12 Gauge - 250 V AC / 20 A - Black - 6 ft Cord Length - IEC 60320 C20 / IEC 60320 C19 - North America - Heavy Duty, P-Lock

Tripp Lite series P032-E06 Power Extension Cord - For Computer, Monitor, HDTV, PDU, Printer, Server, Tablet, UPS, Switch, Network Device - 14 Gauge - 250 V AC / 15 A, 120 V AC, 230 V AC - Black - 6 ft Cord Length - IEC 60320 C13 / IEC 60320 C20 - International - P-Lock, Lockable

C15-to-C14 Power Cable for Network Devices That Require a Heavy-Gauge ConnectionThis power extension cord features 14 AWG wire suitable for high power connections, making it a reliable solution for large server applications that require a higher-rated, heavier-gauge cable. The P018-E06 is designed for higher-temperature devices, such as PoE (Power over Ethernet) switches with high-wattage power supplies, and similar network components. The six-foot (1.8-meter) length helps reduce cable clutter by providing a tailor-made fit between the device and the PDU in a crowded rack enclosure. Forms a Special Locking Connection with a P-Lock OutletThe P-Lock C14 connector forms a secure connection with a PDU with a P-Lock outlet, including Eaton G4 and newer PDUs with C13 and C39 outlets. The P-Lock connection helps reduce costly downtime caused by accidental cable disconnections in a crowded rack or PDU space. The P018-E06 lets you replace a non-locking C14/C15 cable or upgrade an entire PDU application by pairing with an Eaton PDU or other PDU with P-Lock outlets.

Features | 20A C20-to-C21 Power Cable for Network Devices That Require a Heavy-Gauge ConnectionThis heavy-duty cord features 12 AWG wire suitable for high power connections, making it a reliable solution for large server applications that require a higher-rated, heavier-gauge cable, including AI/machine-learning data centers. The six-foot (1.8-meter) length helps reduce cable clutter by providing a tailor-made fit between the device and the PDU or UPS in a crowded rack enclosure. Recommended for High-Temperature EnvironmentsThe P035-006-ABL can be used to connect a blade server, large router or network switch with a C22 inlet, usually found on high-powered, high-temperature (overall operating temperature maximum 105°C/221°F) equipment, to a PDU or UPS system. It's an ideal upgrade to a power cord with improved temperature threshold for data center applications in which temperature control and fire safety are high priorities. Blue Jacket Helps Avoid Misidentification That Can Cause Costly DowntimeThe UL-listed cable has a blue PVC jacket with fully molded blue ends, which is easy to identify quickly in a crowded PDU or UPS system and helps prevent the cable from becoming accidentally disconnected.
Specs
Be the first to ask a question.
We’ll try to get your question answered within 24 hours by a Best Buy customer or brand representative.