APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. Switched outlets allow for turning outlets on or off remotely. Outlet and PDU level power metering provide power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model's input power cord is NEMA L6-30P and features 20 count C13/C15/C19/C21 combo outlets and 20 count C13/C15 outlets. More from the Manufacturer
This product doesn't have any reviews yet.

APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. Switched outlets allow for turning outlets on or off remotely. Outlet and PDU level power metering provide power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model's input power cord is NEMA L6-30P and features 20 count C13/C15/C19/C21 combo outlets and 20 count C13/C15 outlets. More from the Manufacturer

Keep your electronic devices protected with the Insignia 10-Outlet / 2-USB-C / 1-USB 2,400 Joules Surge Protector Strip with 6 ft. Power Cord. It’s rated to protect your equipment against power surges and spikes up to 2,400 joules. Charge multiple devices with eight standard-spaced AC outlets, two wide-spaced AC outlets, two USB-C ports and one USB port. Enjoy flexibility when setting up your space with a 6-foot cord featuring a low-profile 45° offset plug that doesn’t block other outlets.

Perfect for home or office, this 12 AC outlet surge protector with 8-foot cord keeps your electronics and appliances safe via 3780 joules of surge protection. Take advantage of extra room to conveniently plug in larger connectors, a slim profile that saves space, and enjoy peace of mind with our best-in-class 300,000 CEW.

Don’t let a missing or damaged power cord prevent you from using your electronics. Instead of replacing the whole device, use the Best Buy essentials 6' 2-Slot Non-Polarized Power Cord. This non-polarized, two-prong design works with select electronic devices, including PlayStation 5 or Xbox Series X and S gaming systems – just confirm the shape of the power port against your device to ensure compatibility. The 6 ft. cord is designed for indoor use only, granting you flexible placement options when you’re inside. Its black design blends in with the rest of your cords and electronics for a discreet look. Plus, it’s backed by Best Buy so you can rely on it to safely power your electronics.
| Pros for APC - NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 5.0kW, 1Phase, 208V, 30A, L6-30P, 40 Outlet - Switched - Black | |||
|---|---|---|---|
| There were no pros for this product— | Overall Performance, Number of Outlets, Cord Length, Surge Protection, Port Design | Overall Performance, Number of Outlets, Surge Protection, Cord Length, Design | Compatibility, Quality, Power Cord, Fit, Length |
| Cons for APC - NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 5.0kW, 1Phase, 208V, 30A, L6-30P, 40 Outlet - Switched - Black | |||
| There were no cons for this product— | There were no cons for this product— | There were no cons for this product— | Polarized |