HQRP - 60 Amp 250 V RK5 Dual Element Time-Delay Fuse 2-Pack for Bussmann FRN-R-60
Reviews coming soon
About this product
The HCNR060 60 Amp 250 V dual element time-delay fuse is built to protect electrical systems from overloads and short circuits while reducing nuisance openings during temporary motor overloads and surge currents. Its dual element design provides both high-performance short-circuit protection and dependable overload protection, including the ability to hold an overload up to five times the amp rating for at least ten seconds to support motor starting conditions. Rated for high interrupting capacity (250 V AC 200 kA and 150-125 V DC 50 kA), this Class RK5 fuse is suited for demanding protection needs in service entrance switches, switchboard mains and feeders, motor control centers, and motor branches. The cylindrical body measures 13/16 in x 3 in (20.7 mm x 76.2 mm) and the package includes two fuses. Compatible with Bussmann BP/FRN-R-60, FRN-R-60 / Edison ECNR60 / Littelfuse FLNR060.T, FLN-R-60, FLNR-60. The product complies with UL248-12 specifications. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.
Features
60 A 250 V time-delay fuse
Circuit protection: 60 A, 250 V dual element time-delay fuse helps prevent damage from overloads and short circuits; Pack size: Includes 2 fuses for replacements and spares
Compatibility and replacements
Equipment match: Compatible with Bussmann BP/FRN-R-60, FRN-R-60; Replacement for Edison ECNR60; Replacement for Littelfuse FLNR060.T, FLN-R-60, FLNR-60
Dual element overload handling
Motor-friendly design: Dual element construction tolerates temporary surge currents; Overload performance: Holds up to 5x amp rating for at least 10 s to help reduce nuisance fuse openings
High interrupting capacity
Fault protection: 250 V AC interrupt rating 200 kA for high short-circuit capacity; DC capability: 150-125 V DC interrupt rating 50 kA supports demanding applications
RK5 class size and applications
Dimensions: 13/16 in x 3 in (20.7 mm x 76.2 mm) cylindrical fuse; Classification: Class RK5 time-delay; Typical uses: Service entrance switches, switchboard mains and feeders, motor control centers, motor branches; Compliance: Meets UL248-12
Specifications
- BrandHQRPModel Number887774004102604Product Name60 Amp 250 V RK5 Dual Element Time-Delay Fuse 2-Pack for Bussmann FRN-R-60Amperage60 amperesProduct Safety Certifications and Standard(s)NoneProduct Weight0.12 pounds
Reviews
This product doesn't have any reviews yet.
Compare similar products

The HCNR060 60 Amp 250 V dual element time-delay fuse is built to protect electrical systems from overloads and short circuits while reducing nuisance openings during temporary motor overloads and surge currents. Its dual element design provides both high-performance short-circuit protection and dependable overload protection, including the ability to hold an overload up to five times the amp rating for at least ten seconds to support motor starting conditions. Rated for high interrupting capacity (250 V AC 200 kA and 150-125 V DC 50 kA), this Class RK5 fuse is suited for demanding protection needs in service entrance switches, switchboard mains and feeders, motor control centers, and motor branches. The cylindrical body measures 13/16 in x 3 in (20.7 mm x 76.2 mm) and the package includes two fuses. Compatible with Bussmann BP/FRN-R-60, FRN-R-60 / Edison ECNR60 / Littelfuse FLNR060.T, FLN-R-60, FLNR-60. The product complies with UL248-12 specifications. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.

Designed to protect electrical circuits from overloads and short circuits, this Class RK5 dual-element time-delay fuse (model HCNR020) supports temporary motor overloads and surge currents while maintaining strong short-circuit protection. Rated 20 A and 250 V AC with high interrupting capacity up to 200 kA (and 125 V-150 V DC up to 50 kA), it helps reduce nuisance blows in motor and feeder applications by holding an overload up to 5x the amp rating for at least 8 s. The 9/16 in x 2 in (14.3 mm x 50.8 mm) size supports standard installations in service entrance switches, switchboard mains and feeders, motor control centers, and motor branch circuits, and complies with UL248-12 specifications. Compatible with Bussmann BP/FRN-R-20, Edison ECNR20, Littelfuse FLNR020.T / FLN-R-20 / FLNR-20; includes 2 fuses per package. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.

HCNR015 dual element time-delay fuse set is built to protect electrical circuits from overloads and short circuits while helping reduce nuisance openings caused by temporary motor inrush. Each Class RK5 fuse is rated 15 A and 250 V, with high interrupting capacity up to 200 kA at 250 V AC and 50 kA at 150-125 V DC, making it suitable for demanding protection needs in service entrance switches, switchboard mains and feeders, motor control centers, and motor branch circuits. The dual element design supports short-circuit and overload protection, holding up to five times the amp rating for at least 8 seconds to tolerate brief startup surges. Standard body size is 9/16 in x 2 in (14.3 mm x 50.8 mm). Complies with UL248-12 specifications and is compatible with Bussmann BP/FRN-R-15 / Edison ECNR15 / Littelfuse FLNR015.T / FLN-R-15 / FLNR-15. Package includes 2 fuses. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.

Protect solar power circuits with this 2-pack ATPV-63LD solar PV DIN rail fuse holder set designed for photovoltaic (PV) systems. Each holder supports up to 1500 VDC and 35 A and is built for 10 x 85 mm PV fuses, including 10 x 85 mm 20 A fuses in the box. The UL listed design is well-suited for PV combiner boxes, inverters, photovoltaic string circuits, and photovoltaic array protection, helping reduce downtime by providing dependable overcurrent protection. Installation is simplified with 35 mm DIN rail mounting for clean, organized panel layouts. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.
Specs
Be the first to ask a question.
We’ll try to get your question answered within 24 hours by a Best Buy customer or brand representative.