Skip to contentGo to Product Search
Main Content

HQRP - HCNR015 15 A 250 V RK5 Time-Delay Dual Element Fuse 2-Pack Replacement - BP/FRN-R-15 ECNR15 FLNR-15

Model: 887774004102602
SKU: 12522954

Reviews coming soon

Sold & shipped by

About this product

HCNR015 dual element time-delay fuse set is built to protect electrical circuits from overloads and short circuits while helping reduce nuisance openings caused by temporary motor inrush. Each Class RK5 fuse is rated 15 A and 250 V, with high interrupting capacity up to 200 kA at 250 V AC and 50 kA at 150-125 V DC, making it suitable for demanding protection needs in service entrance switches, switchboard mains and feeders, motor control centers, and motor branch circuits. The dual element design supports short-circuit and overload protection, holding up to five times the amp rating for at least 8 seconds to tolerate brief startup surges. Standard body size is 9/16 in x 2 in (14.3 mm x 50.8 mm). Complies with UL248-12 specifications and is compatible with Bussmann BP/FRN-R-15 / Edison ECNR15 / Littelfuse FLNR015.T / FLN-R-15 / FLNR-15. Package includes 2 fuses. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.

Features

  • 15 A 250 V circuit protection

    Amperage and voltage: Rated 15 A, 250 V; helps protect circuits from overloads and short circuits to reduce equipment damage and downtime

  • Dual element time-delay design

    Motor startup handling: Time-delay dual element construction; holds up to 5x amp rating for at least 8 s to tolerate temporary overloads and reduce nuisance openings

  • High interrupting capacity ratings

    Interrupt specs: 250 V AC up to 200 kA and 150-125 V DC up to 50 kA; supports reliable protection in high-fault-current applications

  • Standard RK5 size and 2-pack

    Dimensions and quantity: 9/16 in x 2 in (14.3 mm x 50.8 mm); includes 2 fuses to keep spares on hand or service multiple circuits

  • Replacement compatibility

    Cross references: Replacement for Bussmann BP/FRN-R-15; compatible with Edison ECNR15 and Littelfuse FLNR015.T / FLN-R-15 / FLNR-15

Specifications

  • Brand
    HQRP
    Model Number
    887774004102602
    Product Name
    HCNR015 15 A 250 V RK5 Time-Delay Dual Element Fuse 2-Pack Replacement - BP/FRN-R-15 ECNR15 FLNR-15
    Amperage
    15 amperes
    Product Safety Certifications and Standard(s)
    None
    Product Weight
    0.1 pounds
Sponsored

Reviews

This product doesn't have any reviews yet.

Compare similar products

HQRP - HCNR015 15 A 250 V RK5 Time-Delay Dual Element Fuse 2-Pack Replacement - BP/FRN-R-15 ECNR15 FLNR-15
HQRP - HCNR015 15 A 250 V RK5 Time-Delay Dual Element Fuse 2-Pack Replacement - BP/FRN-R-15 ECNR15 FLNR-15

HCNR015 dual element time-delay fuse set is built to protect electrical circuits from overloads and short circuits while helping reduce nuisance openings caused by temporary motor inrush. Each Class RK5 fuse is rated 15 A and 250 V, with high interrupting capacity up to 200 kA at 250 V AC and 50 kA at 150-125 V DC, making it suitable for demanding protection needs in service entrance switches, switchboard mains and feeders, motor control centers, and motor branch circuits. The dual element design supports short-circuit and overload protection, holding up to five times the amp rating for at least 8 seconds to tolerate brief startup surges. Standard body size is 9/16 in x 2 in (14.3 mm x 50.8 mm). Complies with UL248-12 specifications and is compatible with Bussmann BP/FRN-R-15 / Edison ECNR15 / Littelfuse FLNR015.T / FLN-R-15 / FLNR-15. Package includes 2 fuses. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.

Unique Bargains - 100uF CBB60 Running Capacitor, AC 250V 2 Wires 50/60Hz Cylinder 100x55mm for Water Pumps, Washing Machines - White

Suitable for the start-up of single-phase motors with frequency of 50Hz and 60Hz, such as air compressors, water pumps, pressure washers, air conditioners, washing machines, motors, generators, HVAC, fans, drills, splitters, saws, grinders, etc.

HQRP - 20 Amp 250 V RK5 Dual-Element Time-Delay Fuse 2-Pack - Replacement for Bussmann BP/FRN-R-20

Designed to protect electrical circuits from overloads and short circuits, this Class RK5 dual-element time-delay fuse (model HCNR020) supports temporary motor overloads and surge currents while maintaining strong short-circuit protection. Rated 20 A and 250 V AC with high interrupting capacity up to 200 kA (and 125 V-150 V DC up to 50 kA), it helps reduce nuisance blows in motor and feeder applications by holding an overload up to 5x the amp rating for at least 8 s. The 9/16 in x 2 in (14.3 mm x 50.8 mm) size supports standard installations in service entrance switches, switchboard mains and feeders, motor control centers, and motor branch circuits, and complies with UL248-12 specifications. Compatible with Bussmann BP/FRN-R-20, Edison ECNR20, Littelfuse FLNR020.T / FLN-R-20 / FLNR-20; includes 2 fuses per package. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.

HQRP - 15 A 250 V RK5 Dual-Element Time-Delay Fuse - Replacement for Bussmann BP/FRN-R-15, Edison ECNR15

The HCNR015 is a 15 A dual-element time-delay fuse designed to protect electrical systems from overloads and short circuits while reducing nuisance openings caused by temporary motor startup surges. Built in a Class RK5 9/16 in x 2 in (14.3 mm x 50.8 mm) size, it is designed to deliver both reliable overload protection and strong short-circuit protection, including high interrupting capacity ratings of 250 V AC 200 kA and 125-150 V DC 50 kA. It complies with UL248-12 specifications and is well suited for service entrance switches, switchboard mains and feeders, motor control centers, and motor branch circuits where time-delay performance is needed. Compatible with Bussmann BP/FRN-R-15 / Edison ECNR15 / Littelfuse FLNR015.T / FLN-R-15 / FLNR-15. Disclaimer: This is not an Original Equipment Manufacturer (OEM) product, HQRP branded product is a replacement. All brand names and logos are registered trademarks of their respective owners. Any use of the brand names or model designations for this product are made solely for purposes of demonstrating compatibility.

Specs

Be the first to ask a question.

We’ll try to get your question answered within 24 hours by a Best Buy customer or brand representative.

No content
Sponsored