Need to run a server, UPS, or rack PDU with an IEC C20 inlet from a 208V or 240V circuit with a NEMA 6-20 outlet? This Cable Leader NEMA 6-20P to IEC C19 power cord plugs into a 20 amp 6-20R receptacle and carries the full 20A 250V rating end to end, because the 6-20P plug, the 12 AWG conductors, and the C19 connector are all rated for 20 amps. Built with 12 gauge three-conductor cable in a black SJT jacket, with fully molded plugs and strain relief at both ends. Compatible with any device using an IEC C20 inlet on a 208V, 220V, or 240V supply, including servers, UPS units, rack PDUs with C20 input, high-power network switches, and ASIC miners; for loads that run around the clock, keep continuous draw at 16A or less. UL Listed and RoHS compliant. Best for: 208V/240V data center, server rack, and equipment power from a NEMA 6-20R outlet. Not for: 120V household outlets, NEMA 6-15R outlets, twist-lock L6-20 receptacles, or devices with a C14 inlet.

Features
  • Full 20A 250V Rating from Plug to C19 Connector

    Every part of this heavy duty power cord is rated for 20 amps: the NEMA 6-20P plug, the 12 AWG conductors, and the IEC C19 connector. That supports up to 4,800 watts at 240V or 4,160 watts at 208V for high-wattage server power supplies, UPS units, and rack PDUs. For equipment that runs 24/7, size the continuous load at 16A or less, which is 80 percent of a 20A circuit.

  • 12 AWG SJT Cable with Molded Plug and C19 Connector

    Three 12 gauge conductors keep voltage drop low, even on the 15 ft length, inside a flexible black SJT jacket for indoor rack and equipment-room use. The 6-20P plug and the IEC 60320 C19 connector (IEC 320 C19) are fully molded with integrated strain relief, so the cord holds up to repeated seating in a C20 inlet and routing through cable managers. UL Listed and RoHS compliant.

  • Check Your Outlet First: NEMA 6-20R and C20 Inlet Only

    Not for 120V outlets, NEMA 6-15R, twist-lock L6-20R, or C14 inlets. Quick check: outlet marked 6-20R or 20A 250V, one horizontal slot plus one T-slot? Yes. Vertical slot plus T-slot (5-20R, 120V)? No. Two horizontal slots only (6-15R)? No. Device inlet a wide C20 with 3 horizontal pins? Yes. Smaller C14 inlet? No, choose our 6-20P to C13 cord. Compatible with any device using an IEC C20 inlet.

  • Five Lengths, from 3 ft Rack Jumper to 15 ft Floor Run

    Choose 3 ft or 6 ft to connect a rack PDU or UPS to a nearby 6-20R receptacle without coiling slack, 8 ft or 10 ft to reach a wall outlet from inside a server rack or equipment shelf, or 15 ft for longer runs across an equipment room. Every length uses the same 12 AWG, 20A 250V SJT construction, so you can standardize on one 20 amp power cord and one C19 cord style across the whole row.

  • Sample-Tested Production - Cable Leader Direct Support

    Each cord is sample-tested during production for electrical continuity and manufactured to RoHS environmental standards. If your cord arrives defective or stops working in normal use, Cable Leader handles replacement requests directly, with no manufacturer redirects. Safety note: plug only into a properly installed 208V to 240V NEMA 6-20R circuit, and never exceed the 20A rating of the cord, outlet, or breaker.

Specifications
  • Cable Length
    3 feet
    Connector Type (End 1)
    NEMA 6-20
    Gender (End 1)
    Male
    Connector Type (End 2)
    IEC/EN 60320 (IEC 320)
    Gender (End 2)
    Female
    In-Wall Rated
    No
Sponsored

Reviews

This product doesn't have any reviews yet.

Compare similar products

Cable Leader - NEMA 6-20P to IEC C19 Power Cord, Heavy Duty 12 AWG 20A 250V for 208V/240V Server, UPS, Rack PDU - Black
Cable Leader - NEMA 6-20P to IEC C19 Power Cord, Heavy Duty 12 AWG 20A 250V for 208V/240V Server, UPS, Rack PDU - Black

Need to run a server, UPS, or rack PDU with an IEC C20 inlet from a 208V or 240V circuit with a NEMA 6-20 outlet? This Cable Leader NEMA 6-20P to IEC C19 power cord plugs into a 20 amp 6-20R receptacle and carries the full 20A 250V rating end to end, because the 6-20P plug, the 12 AWG conductors, and the C19 connector are all rated for 20 amps. Built with 12 gauge three-conductor cable in a black SJT jacket, with fully molded plugs and strain relief at both ends. Compatible with any device using an IEC C20 inlet on a 208V, 220V, or 240V supply, including servers, UPS units, rack PDUs with C20 input, high-power network switches, and ASIC miners; for loads that run around the clock, keep continuous draw at 16A or less. UL Listed and RoHS compliant. Best for: 208V/240V data center, server rack, and equipment power from a NEMA 6-20R outlet. Not for: 120V household outlets, NEMA 6-15R outlets, twist-lock L6-20 receptacles, or devices with a C14 inlet.

Cable Leader - NEMA 6-20P to IEC C13 Power Cord, Heavy Duty 14 AWG 15A 250V for 208V/240V Server, UPS, PDU, Workstation - Black

Need to power a server, UPS, or high-wattage workstation from a 208V or 240V circuit with a 20 amp NEMA 6-20R outlet, but the equipment only shipped with a standard 120V cord? This Cable Leader NEMA 6-20P to IEC C13 power cord connects any device with a C14 inlet directly to a 6-20R receptacle. The plug matches the 20A outlet, while the C13 end sets the cord rating at 15A 250V, so the device must draw 15 amps or less. Built with 14 AWG three-conductor copper wire, a 105C SJT jacket, and fully molded plugs with strain relief at both ends. Compatible with any device using an IEC C14 inlet on a 208V, 220V, or 240V supply, including servers, UPS units, rack PDUs with C14 input, network switches, and 240V workstations; it does not fit 120V wall outlets, NEMA 6-15R outlets, C20 inlets, or twist-lock L6 receptacles. UL Listed, RoHS and REACH compliant. Best for: 208V/240V rack and workstation power from a NEMA 6-20R outlet. Not for: 120V household outlets, 6-15R outlets, C19/C20 equipment, or loads above 15A.

Cable Leader - NEMA L5-20P to IEC C19 Power Cord, Twist Lock Heavy Duty 12 AWG 20A 125V for Server, UPS, Rack PDU, Network Switch - Black

Running a server, UPS, or rack PDU on a dedicated 20 amp 120V circuit with a NEMA L5-20R twist-lock receptacle, and the straight-blade cord in the box will not fit? This Cable Leader NEMA L5-20P to IEC C19 power cord locks into the L5-20R outlet with a quarter turn and feeds any device with a C20 inlet, rated 20A 125V so a fully loaded rack server or 2U UPS runs on one cord with no adapter. Built with 12 AWG three-conductor copper wire, a 105C SJT jacket, and fully molded strain-relief ends for racks and network closets. Compatible with any device using an IEC C20 inlet on a 120V 20A supply, including rack servers, UPS units, rack PDUs with a C20 input, network switches, storage arrays, and pro audio amplifiers; it does not fit 5-15R or 5-20R straight-blade wall outlets, 250V L6-20R receptacles, or C14 inlets. UL Listed, RoHS and REACH compliant. Best for: locking 120V 20A power to server, UPS, PDU, and network gear from an L5-20R outlet. Not for: straight-blade wall outlets, 250V circuits, C13/C14 equipment, or loads above 20A.

Cable Leader - 14 AWG NEMA 5-15P to IEC C19 Heavy Duty PDU Power Cord, 15A 125V, UL Listed, for UPS, Server and Rack PDU - Black

Need to power a UPS, rack PDU, or server with a C20 inlet from a standard wall outlet? This Cable Leader power cord pairs a NEMA 5-15P 3-prong grounded wall plug with an IEC 60320 C19 connector, delivering wall-outlet power directly to higher-power equipment without a PDU-to-device jumper. It is built from 14 AWG, 3-conductor copper wire with a flame-retardant VW-1 SJT jacket and fully molded ends, rated 15A at 125V for indoor use, and the cordset is UL Listed. The C19 connector fits the C20 inlets commonly found on rack PDUs, larger UPS units, servers, and core switches; it is larger than the common C13 and will not fit C14 inlets, and the 5-15P plug limits the cordset to 15A even though some C19 hardware exists in 20A versions. Best for: powering a C20-inlet UPS, PDU, or server from a standard North American wall outlet within 15A/125V. Not for: C13/C14 devices, 20A applications, 250V circuits, or outdoor use.

Specs

Be the first to ask a question.

We’ll try to get your question answered within 24 hours by a Best Buy customer or brand representative.

No content
Sponsored