Eaton Tripp Lite Series Power Cord, C14 to C21 - Heavy-Duty, 15A, 250V, 14 AWG, 6 ft. (1.8 m), For Computer - White
Reviews coming soon
About this product
Features | 15A C14-to-C21 Power Cable for Network Devices That Require a Heavy-Gauge ConnectionThis heavy-duty cord features 14 AWG wire suitable for high power connections, making it a reliable solution for large server applications that require a higher-rated, heavier-gauge cable, including AI/machine-learning data centers. The six-foot (1.8-meter) length helps reduce cable clutter by providing a tailor-made fit between the device and the PDU or UPS in a crowded rack enclosure. Recommended for High-Temperature EnvironmentsThe P037-006-AWH can be used to connect a blade server, large router or network switch with a C22 inlet, usually found on high-powered, high-temperature (overall operating temperature maximum 105°C/221°F) equipment, to a PDU or UPS system. It's an ideal upgrade to a power cord with improved temperature threshold for data center applications in which temperature control and fire safety are high priorities. White Jacket Helps Avoid Misidentification That Can Cause Costly DowntimeThe UL-listed cable has a white PVC jacket with fully molded white ends, which is easy to identify quickly in a crowded PDU or UPS system and helps prevent the cable from becoming accidentally disconnected.
Features
Eaton Tripp Lite Series Power Cord, C14 to C21 - Heavy-Duty
Features | 15A C14-to-C21 Power Cable for Network Devices That Require a Heavy-Gauge ConnectionThis heavy-duty cord features 14 AWG wire suitable for high power connections, making it a reliable solution for large server applications that require a higher-rated, heavier-gauge cable, including AI/machine-learning data centers. The six-foot (1.8-meter) length helps reduce cable clutter by providing a tailor-made fit between the device and
Specifications
- Cable Length6.0 feetConnector Type (End 1)IEC/EN 60320 (IEC 320)Connector Type (End 2)IEC/EN 60320 (IEC 320)
Reviews
This product doesn't have any reviews yet.
Compare similar products

Features | 15A C14-to-C21 Power Cable for Network Devices That Require a Heavy-Gauge ConnectionThis heavy-duty cord features 14 AWG wire suitable for high power connections, making it a reliable solution for large server applications that require a higher-rated, heavier-gauge cable, including AI/machine-learning data centers. The six-foot (1.8-meter) length helps reduce cable clutter by providing a tailor-made fit between the device and the PDU or UPS in a crowded rack enclosure. Recommended for High-Temperature EnvironmentsThe P037-006-AWH can be used to connect a blade server, large router or network switch with a C22 inlet, usually found on high-powered, high-temperature (overall operating temperature maximum 105°C/221°F) equipment, to a PDU or UPS system. It's an ideal upgrade to a power cord with improved temperature threshold for data center applications in which temperature control and fire safety are high priorities. White Jacket Helps Avoid Misidentification That Can Cause Costly DowntimeThe UL-listed cable has a white PVC jacket with fully molded white ends, which is easy to identify quickly in a crowded PDU or UPS system and helps prevent the cable from becoming accidentally disconnected.

Need to power a server, UPS, or high-wattage workstation from a 208V or 240V circuit with a NEMA 6-15R or 6-20R outlet, but the equipment only shipped with a standard 120V cord? This Cable Leader NEMA 6-15P to IEC C13 power cord connects any device with a C14 inlet directly to a 240V receptacle, rated 15A 250V so a full-load rack server runs on one cord with no adapter. Built with 14 AWG three-conductor copper wire, a 105C SJT jacket, and fully molded plugs with strain relief at both ends for rack installations and under-desk cable runs. Compatible with any device using an IEC C14 inlet on a 208V, 220V, or 240V supply, including servers, UPS units, rack PDUs with C14 input, network switches, storage arrays, and 240V workstations; it does not fit standard 120V NEMA 5-15R wall outlets, C20 inlets, or twist-lock L6 receptacles. UL Listed, RoHS and REACH compliant. Best for: 208V/240V rack and workstation power from a 6-15R or 6-20R outlet. Not for: 120V household outlets, C19/C20 equipment, or loads above 15A.

Your rack PDU or UPS needs 250V, but the receptacle on the wall is a round twist-lock, not a standard three-prong outlet. This Cable Leader cord connects a NEMA L6-20P twist-lock plug to an IEC 60320 C13 outlet, delivering 15A at 250V for a 3,750-watt maximum load over three 14 AWG copper conductors. A quarter turn seats the plug in an L6-20R receptacle and holds it, so vibration or a cable pull cannot drop power. The SJT jacket is rated for hard service and both connector bodies are fully molded with integrated strain relief. Compatible with any equipment carrying an IEC C14 inlet rated for 250V operation: rack-mount PDUs, UPS systems, rack servers, network switches, KVM switches, and storage arrays. The plug end needs a NEMA L6-20R receptacle and will not fit a standard 125V outlet; L6-20P is not interchangeable with the 125V L5-20P. Best for: 208V and 240V equipment fed from an L6-20R twist-lock receptacle. Not for: 120V devices or loads above 15A. UL Listed and RoHS compliant.

Need to run a server, UPS, or rack PDU with an IEC C20 inlet from a 208V or 240V circuit with a NEMA 6-20 outlet? This Cable Leader NEMA 6-20P to IEC C19 power cord plugs into a 20 amp 6-20R receptacle and carries the full 20A 250V rating end to end, because the 6-20P plug, the 12 AWG conductors, and the C19 connector are all rated for 20 amps. Built with 12 gauge three-conductor cable in a black SJT jacket, with fully molded plugs and strain relief at both ends. Compatible with any device using an IEC C20 inlet on a 208V, 220V, or 240V supply, including servers, UPS units, rack PDUs with C20 input, high-power network switches, and ASIC miners; for loads that run around the clock, keep continuous draw at 16A or less. UL Listed and RoHS compliant. Best for: 208V/240V data center, server rack, and equipment power from a NEMA 6-20R outlet. Not for: 120V household outlets, NEMA 6-15R outlets, twist-lock L6-20 receptacles, or devices with a C14 inlet.
Specs
Be the first to ask a question.
We’ll try to get your question answered within 24 hours by a Best Buy customer or brand representative.














































